Removed Pin From Net: NetName=+3.3 Pin=Q1-3
Removed Pin From Net: NetName=+3.3 Pin=Q2-3
Removed Pin From Net: NetName=+3.3 Pin=Q3-3
Removed Pin From Net: NetName=+3.3 Pin=Q4-3
Removed Pin From Net: NetName=NetQ1_1 Pin=U3-6
Removed Pin From Net: NetName=NetQ2_1 Pin=U3-8
Removed Pin From Net: NetName=NetQ3_1 Pin=U3-9
Removed Pin From Net: NetName=NetQ4_1 Pin=U3-12
Change Component Footprint: Designator=R5 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R6 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R7 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R8 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R9 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R10 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R11 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R12 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R13 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R14 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R15 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R16 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R17 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R18 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R19 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=R20 Old Footprint=AXIAL-0.3 New Footprint=0402
Change Component Footprint: Designator=Q1 Old Footprint=SOT-23B_N New Footprint=s8550
Change Component Footprint: Designator=Q2 Old Footprint=SOT-23B_N New Footprint=s8550
Change Component Footprint: Designator=Q3 Old Footprint=SOT-23B_N New Footprint=s8550
Change Component Footprint: Designator=Q4 Old Footprint=SOT-23B_N New Footprint=s8550
Added Pin To Net: NetName=+3.3 Pin=Q1-2
Added Pin To Net: NetName=+3.3 Pin=Q2-2
Added Pin To Net: NetName=+3.3 Pin=Q3-2
Added Pin To Net: NetName=+3.3 Pin=Q4-2
Added Pin To Net: NetName=NetQ1_1 Pin=R5-1
Added Pin To Net: NetName=NetQ1_1 Pin=R6-1
Added Pin To Net: NetName=NetQ2_1 Pin=R7-2
Added Pin To Net: NetName=NetQ2_1 Pin=R8-2
Added Pin To Net: NetName=NetQ3_1 Pin=R9-1
Added Pin To Net: NetName=NetQ3_1 Pin=R10-1
Added Pin To Net: NetName=NetQ4_1 Pin=R11-2
Added Pin To Net: NetName=NetQ4_1 Pin=R12-1
Added Pin To Net: NetName=NetQ1_3 Pin=Q1-3
Added Pin To Net: NetName=NetQ1_3 Pin=U3-6
Added Net: Name=NetQ1_3
Added Pin To Net: NetName=NetQ2_3 Pin=Q2-3
Added Pin To Net: NetName=NetQ2_3 Pin=U3-8
Added Net: Name=NetQ2_3
Added Pin To Net: NetName=NetQ3_3 Pin=Q3-3
Added Pin To Net: NetName=NetQ3_3 Pin=U3-9
Added Net: Name=NetQ3_3
Added Pin To Net: NetName=NetQ4_3 Pin=Q4-3
Added Pin To Net: NetName=NetQ4_3 Pin=U3-12
Added Net: Name=NetQ4_3
Added Room: Name=Sheet1